| VSC 5000 |
|
|
|
 |
The system
specifications:
- High resolution digital 3×CCD firewire colour
video camera with 1360×1024 pixel output per colour and
400 to 1000nm spectral response
- Image display via 21inch flat screen LCD
- Zoom magnification range of 2× to ×85
(approx) on
the standard 53cm (21inch) display monitor
- Modes of illumination:
long wave UV, incident lighting (365nm)
long wave UV, transmitted lighting (365nm)
medium wave UV, incident lighting (313nm)
short wave UV, incident lighting (256nm)
visible and infra red, incident lighting
visible and infra red, transmitted lighting
visible and infra red, oblique lighting
visible and infra red, coaxial incident light for examination
retro-reflective security
features
Visible, incident high intensity spot light, 250W tungsten
halogen lamp with independent low pass and high pass filters
providing 78 different wavebands and zoom lens, providing
a broad beam to a focused spotlight:

- 15 high pass imaging filters in the visible
and near infra red with thresholds at 530, 550, 570, 590,
610, 628, 648, 668, 690, 715, 725, 780, 823, 856 and 1000nm
plus a broadband pass filter 390-610nm
- Continuous interference imaging filter with
an average bandpass of 40nm over the
wavelength range 400 to 1000nm, operated in 3.5nm steps
- Image integration, on-chip with integration
periods of 1/125, 1/60, 1/30, 1/15 1/8,1/4, 1/2, 1, 1.4, 2, 2.8,
4, 5.6, 8, 11, 16, 22 seconds
- Colour measurement, provides CIE colour
co-ordinates & chromaticity diagrams - measures colour
parameters: XYZ, xy, uv, Lab. Displays data on 1931 and 1960 UCS chromaticity charts
- Microspectrometry measures absorption, reflectance, transmission
and fluorescence
spectra. 400 to 1000nm range, sample size down to 16 microns².
Calibration permits
normalisation of spectra
- PC system operating Windows XP
- Network capability
- Remote operation
- Casework management software which enables
images, examiner's notes and other instrument derived data,
such as spectra and diagrams to be stored in casework files.
Images may be annotated and stored with instrument settings
- Image processing software providing:
Side by side comparison of live and stored image
Superimposition of a live and a stored image with adjustable
mix, 0 to 100%
Variable speed image strobe between a live and a stored
image
Left to right image reversal (horizontal mirror reversal)
Top to bottom image reversal (vertical mirror reversal)
Grey level reversal (position to negative)
Image rotation, through 90
Contrast stretch
De-speckle filters (noise reduction)
- Image measurement software providing:
Distance between two points
Area within a user defined box
Radius of a circular feature from three peripheral points
Angle between two lines
Area of user defined shape
Area of selected features, i.e. an alphanumeric character
or logo
- Controls via graphical user interface
- 120 VAC, 60 Hz and 230 VAC, 50 Hz operation
- Suitable for the examination of documents
up to 280mm width of unrestricted length and up to 280 mm
long of unrestricted width.
Back
|
|
 |
 |
 |
 |
| |
VSC 5000
video spectral comparator |
|
 |
|
|
|